Diode lasers operating around 780nm and 785nm are used in a range of scientific, medical and industrial applications. Although these wavelengths are close to the visible red region, they can present significant eye hazards.
At approximately 780–785nm, laser radiation is near the boundary between visible and infrared wavelengths. Depending on the source and exposure conditions, the radiation may not provide the same natural visual warning associated with brighter visible laser light.
The eye can focus laser radiation onto the retina, potentially creating a highly concentrated exposure at the retinal tissue. For this reason, appropriate engineering controls and laser safety eyewear are important when working with hazardous sources.
When selecting glasses for a 780nm or 785nm diode laser, check that the specified wavelength range actually includes the operating wavelength. The optical density should also be appropriate for the laser's power and operating conditions.
Some filters provide broader near-infrared protection and may cover wavelengths beyond 785nm. This can be useful in environments where multiple diode laser systems are present.
The appearance or darkness of the lens should not be used as the main method of determining suitability. Instead, check the manufacturer's wavelength and OD specifications and any applicable EN207 ratings.